Motorized Variable Attenuator for Linearly Polarized Laser Beam 990-0071M

Motorized Variable Attenuator for Linearly Polarized Laser Beam 990-0071M

Motorized variable attenuators with ø 10 mm clear aperture allowing to continuously vary the intensity ratio of exiting s-pol and p-pol beams. Attenuators consist of thin film polarizer, high-performance waveplate and precision opto-mechanics.

Request
delivery Estimated delivery time: 5 - 7 days
Specifications
3D Drawings
Brochures
Description

For Nd:YAG Laser Applications

Aperture diameter 10 mm
Damage threshold 5 J/cm2 pulsed at 1064 nm, typical
Polarization Contrast >1:200


For Femtosecond Applications

Aperture diameter 10 mm
Damage threshold
            for high power laser applications:
>10 mJ/cm2, 50 fs pulse at 800 nm, typical
>100 mJ/cm2, 50 fs pulse at 800 nm, typical
Time dispersion t<4 fs for 100 fs Ti:Sapphire laser pulses
Polarization Contrast >1:200
EKSMA Optics Motorized Variable Attenuators 990-0071M
141.63 kB
download PDF

This Motorized Variable Attenuator / Beamsplitter consists of special design Opto-mechanical Adapter for Polarizer at 56° 840-0117A or 840-0118A and Precision Opto-mechanical Holder 840-0193. Thin Film Brewster type polarizer, which reflects s-polarized light at 56° while transmitting p-polarized light, is housed into the Adapter for Polarizer at 56°. Quartz Half Waveplates are housed in Motorized Rotation Stage 960-0161. The intensity ratio of those two beams may be continuously varied without alteration of other beam parameters by rotating the waveplate.

 

The intensity of either exit beam, or their intensity ratio, can be controlled over a wide dynamic range. P-polarization could be selected for maximum transmission, or high-purity s-polarization could be reflected when maximum attenuation of the transmitted beam takes place. The holder 840-0193 allows to adjust angle of incidence of the Thin Film Brewster type polarizer by ±2° and to get the maximum polarization contrast.

 

Note: Controller and power supply should be ordered separately.