Laser Harmonic Separators

These harmonic separators comprise a dichroic reflector coating and should be applied on the front surface of high precision windows. They are used to separate the various harmonic components of frequency doubled laser systems by selective spectral reflection and transmission. In all cases one wavelength is selected out by reflection and the other wavelengths are transmitted.

 

Coating number
Wavelength, nm AOI=0°
AOI=45°
Recomm Damage
AOI=0° AOI=45° R/T R, % T, % R, % T, % substrate threshold
2506-i0 2506-i45 200-220/390-450 >90.0 >85 >90.0 >80 UVFS 1 J/cm2 in 10 ns
2510-i0 2510-i45 355/532+1064 >99.0 >93 >99.0 >90 UVFS 1 J/cm2 in 10 ns
2514-i0 2514-i45 380-420/720-820 >99.0 >90 >99.0 >90 UVFS, BK7 1 J/cm2 in 10 ns
2518-i0 2518-i45 532/1064 >99.5 >95 >99.5 >95 UVFS, BK7 1 J/cm2 in 10 ns
2522-i0 2522-i45 600/1200 >99.5 >95 >99.5 >95 UVFS, BK7 2 J/cm2 in 10 ns
2526-i0 2526-i45 800/400 >99.5 >90 >99.5 >90 UVFS, BK7 2 J/cm2 in 10 ns
2530-i0 2530-i45 1064/400-700 >99.5 >85 >99.5 >80 UVFS, BK7 2 J/cm2 in 10 ns
2534-i0 2534-i45 1064/532 >99.5 >93 >99.5 >90 UVFS, BK7 2 J/cm2 in 10 ns

Contact us for other wavelengths and AOI's values.